Ventilator Operating Specifications Ventilator parameter ranges Tidal volume range: 5 to 1500ml ( Volume Control, PCV-VG and SIMV volume 20 to 1500ml) (PCV modes 5 to 1500ml) Incremental settings: 20 to 50 mL (increments of 1 mL) 50 to 100 mL (increments of 5 mL) 100 to 300 mL (increments of 10 mL) 300 to 1000 mL (increments of 25 mL) 1000 to 1500 mL (increments of 50 mL) Minute volume range: Less than 0.1 to 99.9 L/min Pressure (Pinspired) range: 5 to 60 cmH2O (increments of 1 cmH2O) 5 to 1500 mL volume delivery Pressure (Pmax) range: 12 to 100 cmH2O (increments of 1 cmH2O) Pressure (Psupport) range: Off, 2 to 40 cmH2O (increments of 1 cmH2O) Rate: 4 to 100 breaths per minute for Volume Control and Pressure Control; 2 to 60 breaths per minute for SIMV, PSVPro and SIMV PCV-VG; 4 to 60 bpm for CPAP+PSV (increments of 1 breath per minute) Inspiratory/ expiratory ratio: 2:1 to 1:8 (increments of 0.5) Inspiratory time: 0.2 to 5.0 seconds (increments of 0.1 seconds) (SIMV, PSVPro and CPAP PSV) Trigger window: 0 to 80% (increments of 5% ) Flow trigger: 1 to 10 L/min (increments of 0.5 L/min) 0.2 to 1 L/min (increments of 0.2 L/min) Inspiration termination level: 5 to 75% (increments of 5% ) Inspiratory Pause range: 0-60% Positive End Expiratory Pressure (PEEP) Type: Integrated, electronically controlled Range: OFF, 4 to 30 cmH2O (increments of 1 cmH2O) Ventilator performance Pressure range at inlet: 240 kPa to 700 kPa (35 psig to 100 psig) Peak gas flow: 120 L/min + fresh gas flow Flow valve range: 1 to 120 L/min Flow compensation range: 150 mL/min to 15 L/min Ventilator Accuracy Delivery/monitoring accuracy Volume delivery: > 210 mL = better than 7% à 7 ≤ 210 mL = better than 15 mL < 60 mL = better than 10 mL Pressure delivery: ±10% or ±3 cmH2O PEEP delivery: ±1.5 cmH2O Volume monitoring: > 210 mL = better than 9% ? ≤ 210 mL = better than 18 mL < 60 mL = better than 10 mL Pressure monitoring: ±5% or ±2 cmH2O ALARM SETTINGS Tidal volume (VTE): Low: OFF, 1 to 1500 mL High: 20 to 1600 mL, OFF Minute volume (VE): Low: OFF, 0.1 to 10 L/min High: 0.5 to 30 L/min, OFF Inspired oxygen (FiO2): Low: 18 to 99% ? High: 19 to 100% , OFF Apnea alarm: Mechanical ventilation ON: < 5 mL breath measured in 30 seconds Mechanical ventilation OFF: < 5 mL breath measured in 30 seconds Low airway pressure: 4 cmH2O above PEEP High pressure: 12 to 100 cmH2O (increments of 1 cmH2O) Sustained airway pressure: Mechanical ventilation ON: Pmax < 30 cmH2O, the sustained limit is 6 cmH2O Pmax 30 to 60 cmH2O, the sustained limit is 20% of Pmax Pmax > 60 cmH2O, the sustained limit is 12 cmH2O PEEP and mechanical ventilation ON Sustained limit increases by PEEP minus 2 cmH2O Mechanical ventilation OFF: Pmax ≤ 60 cmH2O, the sustained limit is 50% of Pmax Pmax > 60 cmH2O, the sustained limit is 30 cmH2O Subatmospheric pressure: Paw < -10 cmH2O Audio pause countdown clock: 120 to 0 seconds Ventilator Components Flow transducer Type: Variable orifice flow sensor Dimensions: 22 mm OD and 15 mm ID Location: Inspiratory outlet and expiratory inlet Ventilator screen Display size: 15 inch Pixel format: 1024 x 768 Battery backup Backup power: Demonstrated battery time is up to 90 minutes when fully charged. Battery time under extreme conditions is 30 minutes. Battery type: Internal rechargeable sealed lead acid Communication ports RS-232C compatible serial interface Ethernet Datex-Ohmeda device interface solutions port USB port VGA Output Anesthetic Agent Delivery Delivery Vaporizers: Tec* 6 Plus, Tec 7 Number of positions: 2 (3 as an option) Mounting: Tool-free installation Selectatec* manifold interlocks and isolates vaporizers Airway Modules General M-CAiO, M-CAiOV, M-CAiOVX module software version 3.2 or higher; E-CAiO, ECAiOV, E-CAiOVX Size (WxDxH): 75 x 228 x 112 mm/ 3.0 x 9.0 x 4.4 in Weight: 1.6 kg/3.5 lb Sampling rate: 200 mL/min ±20 mL E-sCAiO, E-sCAiOV Size (WxDxH): 38 x 205 x 113 mm/ 1.5 x 8.1 x 4.4 in Weight: 0.7 kg/1.5 lb Sampling rate: 120 mL/min ±20 mL Automatic compensation for atmospheric pressure variation (500 to 800 mmHg for E-, M-series modules; 495 to 795 mmHg for CARESCAPE modules) temperature and CO2/N2O and CO2/O2 collision broadening effect. Parameter display update interval typically breath-by-breath. Functional alarms for blocked sample line, D-fend check and D-fend replacement. Non-disturbing gases: Ethanol, acetone, methane, nitrogen, nitric oxide, carbon monoxide, water vapor: Maximum effect on readings: CO2 < 0.2 vol % ; O2, N2O < 2 vol % Carbon dioxide (CO2) EtCO2: End-tidal CO2 concentration FiCO2: Inspired CO2 concentration CO2 waveform Measurement range: 0 to 15% (0 to 15 kPa, 0 to 113 mmHg) Accuracy: ±0.2 vol % + 2 % of reading Datex-Ohmeda infrared sensor Adjustable low and high alarm limits for EtCO2 and FiCO2 Respiration rate (RR) Measurement range: 4 to 60 breaths/min for E-, M-series modules 4 to 100 breaths/min for CARESCAPE modules Detection criteria: 1% variation in CO2 Adjustable low and high alarm limits for respiration rate; alarm for apnea Patient Oxygen (O2) FiO2: Inspired O2 concentration EtO2: End-tidal O2 concentration FiO2-EtO2: Inspired-expired difference O2 Measurement Measurement range: 0 to 100% Accuracy: ±1 vol % +2 % of reading Datex-Ohmeda differential paramagnetic sensor Adjustable low and high alarm limits for FiO2 and EtO2; alarm for FiO2 < 18% Nitrous Oxide (N2O) Measurement range: 0 to 100% Accuracy: ±2 vol % +2 % of reading Anesthetic Agent (AA) Halothane, Isoflurane, Enflurane Measurement range: 0 to 6% Accuracy: ±(0.15 vol% +5% of reading) SEVOFLURANE Measurement range: 0 to 8% Accuracy: ±(0.15 vol% +5% of reading) Desflurane Measurement range: 0 to 20% Accuracy: ±(0.15 vol% +5% of reading) Waveform displayed MAC value displayed Identification threshold: 0.15 vol % 1 Agent mixture detection Adjustable high and low alarm limits for EtAA, FiAA Patient Spirometry* Pressure-volume loop Pressure-flow loop Flow-volume loop Airway pressure and flow waveforms Adjustable low and high alarm limits for Ppeak, PEEPtot and MVexp Alarms for MVexp << MVinsp and for MVexp low. Detection through D-lite* or Pedi-lite* flow sensor and gas sampler with following specifications: Compact Airway Modules D-lite Pedi-lite Respiration rate: 4 to 35 4 to 50 breaths/min breaths/min Tidal volume Measurement range: 150 to 15 to 2000 mL 300 mL Accuracy1: ±6% or 30 mL ±6% or 4 mL Minute volume Measurement range: 2 to 20 L/min 0.5 to 5 L/min Accuracy1: ±6% ±6% Airway pressure Measurement range: -20 to +100 cmH2O Accuracy1: ±1 cmH2O Display units: cmH2O, mmHg, kPa, mbar, hPa Flow Measurement range: 1.5 to 0.25 to 25 L/min 100 L/mi I:E Measurement range: 1:4.5 to 2:1 Compliance Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O Airway resistance Measurement range: 0 to 40 cmH2O/L/s CARESCAPE Airway Modules D-lite(+) Pedi-lite(-) Respiration rate: 4 to 35 4 to 70 breaths/min breaths/min Tidal volume Measurement range: 150 to 5 to 2000 mL 300 mL Accuracy1: ±6% or 30 mL ±6% or 4 mL Minute volume Measurement range: 2 to 20 L/min 0.1 to 5 L/min Accuracy1: ±6% ±6% Airway pressure Measurement range: -20 to +100 cmH2O Accuracy1: ±1 cmH2O Display units: cmH2O, mmHg, kPa, mbar, hPa Flow Measurement range: -100 to -25 to 25 L/min 100 L/min I:E Measurement range: 1:4.5 to 2:1 Compliance Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O Airway resistance Measurement range: 0 to 200 cmH2O/L/s Sensor specifications D-lite/ Pedi-lite/ D-lite(+) Pedi-lite(+) Dead space: 9.5 mL 2.5 mL Resistance at 30 L/min: 0.5 cmH2O at 10 L/min: 1.0 cmH2O

Specifications

ManufacturerGENERAL ELECTRIC
ModelAVANCE CS2
Year2019
ConditionUsed
Stock Number9605