The TM-500 syringe pump has long been used for precise control of the injection speed and monitoring process in clinical injection therapy. Multiple alarms, pre-infusion, end of infusion, volume, zero flow, etc.... - Total volume: range: 9999.9 ml (0.1 ml scale), accuracy ± 2%. - Alarms: for pre-infusion, end of infusion, preset volume, zero flow or no start, occlusion, mechanical disengagement, setting error, low battery, mains failure and other device faults. - Atmospheric pressure 86kPa ~ 106kPa - Safety level: Class I, type BF, built-in battery, continuous operation device - Remote control to change mode, set flow rate and all parameters The TM-500 syringe pump has long been used for precise control of the injection speed and monitoring process in clinical injection therapy. Widely used in clinical departments for conventional intravenous injection, anesthetic injection, anticoagulant injection and chemotherapy for cancer patients. Also applicable to medical intensive care units, neurological intensive care units and so on. The TM-500 syringe pump is compatible with ordinary disposable syringes. It is a constant-speed, constant-volume syringe pump. Its operating principle is: The microprocessor precisely controls the precise stepper motor, passes through the mechanical transmission device to generate the translational force, and through various sensors to control the injection speed of the disposable syringes exactly and control the injection process. It's also known as a high-precision intelligent syringe pump. If the injection extension line clogs, the sensor can operate the working syringe pump automatically. When the blockage pressure is restored, it will return to work automatically. Delivery rate range Syringe volume Range 0.1 to 99.9 ml (0.1 ml steps) Total volume Range 9999.9 ml (0.1 ml steps) Accuracy ± 2% Alarms Almost empty, syringe empty, preset volume Injection complete, occlusion, syringe loose, Setting error, low battery, power failure And other device failures. Operating conditions Storage conditions Atmospheric pressure 86kPa ~ 106kPa Safety level Class I, type BF, integrated battery, continuous operation device Dimensions 282 mm (W) x 144 mm (M) x 148 mm (H) Weight 2.3KG

Specifications

ConditionNew
Stock Number5221
Syringe volumerange from 0.1 to 99.9 ml (0.1 ml)
50 ml syringe1000ml / h ~ 1800ml.h (1ml / h step)
30 ml syringe0.1 ml / h ~ 900 ml / h (steps of 0.1 ml / h)
20 ml syringe0.1 ml / h ~ 600 ml / h (steps of 0.1 ml / h)
10 ml syringe0.1 ml / h ~ 300 ml / h (steps of 0.1 ml / h)
5 ml syringe0.1 ml / h ~ 150 ml / h (steps of 0.1 ml / h)
Ambient temperature-30 ℃ ~ +55 ℃
Relative humidity20% ~ 95%
LanguageEnglish