CAMCARDIO 3-CHANNEL ELECTROCARDIOGRAPH

CAMCARDIO 3-CHANNEL ELECTROCARDIOGRAPH

Fr735 (CHF)

Available quantity: 1

orCall + 41 (0)27 720 41 00

Description

Automatic, clear real-time recording of ECG traces and observations. Observations include lead signals, sensitivity, paper speed, filter status, etc. High-resolution thermal printing system (8 dots/mm), no adjustment required, recording frequency over 150Hz. In automatic mode, one touch is all it takes to record data accurately. Control panel with digital keys and touchscreen for fast, easy operation. LCD display for easy data reading. Complies with Class I, Type CF safety standards with defibrillation protection. The device can be plugged directly into an outlet or powered by the internal rechargeable lithium battery. The unit can record up to 150 ECG traces and print for 90 minutes non-stop (battery fully charged). The device's memory capacity is 1000 records, handy for statistics and diagnosis by the attending physician. The device is elegant and quiet. In accordance with safety standards, the device must not be used in the presence of flammable products or gases. The device features a digital signal processor with mains and electro-magnetic emission filters for superior ECG quality. The device automatically measures, analyzes and diagnoses ECG parameters, reducing the physician's workload. Operating environment conditions Use : c) Power supply: AC:100-240V, 50/60Hz Transport & Storage: 1.11 Recording paper specifications: 80mm(Width)*20m(Length) Ultra-fast thermal paper 1.12 Paper speed : Automatic recording: 25mm/s, 50mm/s, error:±5% Heart rate recording: 25mm/s, 50mm/s, error:±5% Manual recording: 5mm/s, 6mm/s, error:±5 Manual recording: 5mm/s, 6.25mm/s,10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error:±5% . 1.13 Sensitivity selection: 2.5, 5, 10, 20,40mm/mV, 5 options, error: ±5% . Standard sensitivity is 10mm/mV±0.2mm/mV. 1.14 Automatic recording: recording is configured according to recording format, automatic mode, automatic lead change, measurement and analysis. 1.15 Manual recording: recording is configured according to recording format & manual lead change. 1.16 Measurement parameters: Heart rate FC, P-R interval, P wave duration, QRS complex duration, T wave duration, Q-T interval, Q-Tc interval, P axis, QRS axis, T axis, R(V5), S(V1), R(V5) +S(V1) 1.17 Product safety model : Class I, Type CF, with defibrillation protection circuit. 1.20 Fuse specifications: 2 pcs φ5*20mm AC : T1.6AL250V

Specifications

ConditionNew
Stock Number5372
Liquid entry protection systemIPX0.
A) ambient temperature-40℃~55℃
B) relative humidity≤95%
Dc7.4V, 3700 mAh Rechargeable lithium battery
D) atmospheric pressure860 hPa~1060 hPa
C) atmospheric pressure500 hPa~1060 hPa
1.2 entryFloat & Defib protection
1.3 bypass12 Standard outlets
1.4 patient leakage current<10µA
1.5 input impedance≥50MΩ
1.6 frequency response0.05Hz~150Hz
1.7 time constancyTime constancy>3.2s
1.8 cmrr>60dB, >100dB (With AC filter)
1.9 common-mode rejection ratio (rrmc)25Hz/35Hz(-3dB)
1.10 recording modeThermal printing
1.18 polarization voltage±300mV
1.19 noise level≤15µVp-p
1.21 dimensions315mm(Length)*215mm(Width)*77mm(Height)
1.22 net weight2.25Kg
Ref. tovamedDA18140